GE Fanuc USB VersaMax USB version of IC200CBL500A. RJ45 (8pin) x USB. All of our cables come with a 30 day money back and a lifetime replacement guarantee. GE Fanuc USB SNP Windows 7 and VersaPro or Proficy Cimplicity ME. VersaMax Modular Provides Superior Versatility VersaMax Modular is control and IO that can be snapped together to provide a compact node with a smaller footprint than typical control/IO combinations. VersaMax Micro Offers Big Performance in a Small Size The Micro line of VersaMax controllers provide superior functionality in a compact package. GE Versamax IC200CHS002 is a box-style i/o carrier, with 36 iec box-style terminals and provides mounting, also the GE Versamax IC200CHS002field has backplane communications  wiring for. The VersaMax Nano is ideal for high-volume applications where cost and fast processor speeds are critical. Programming and configuration is simple and intuitive with Proficy Machine Edition software. GE Fanuc VersaMax PLC Processors for sale eBay.

GE Fanuc Versamax Troubleshooting

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    The VersaMax family of products provides universally-distributed I/O that spans PLC and PC-based architectures. Designed for industrial and commercial automation, VersaMax I/O provides a common, flexible I/O structure for local and remote control applications. The VersaMax PLC provides big-PLC power with a full range of I/O and option modules. VersaMax I/O Stations with Network Interface Modules make it possible to add the flexibility of VersaMax I/O to other types of networks. VersaMax meets UL, CUL, CE, Class1 Zone 2 and Class I Division 2 requirements.

    As a scaleable automation solution, VersaMax I/O combines compactness and modularity for greater ease of use. The 70-mm depth and small footprint of VersaMax I/O enables easy, convenient mounting as well as space- saving benefits. Modules can accommodate up to 32 points of I/O each. (VersaMax® PLC User's Manual, 2006)

    Below is a list of abbreviations we think you should know before continuing:

    • CPU: Central Processing Unit
    • DI: Digital Input Module
    • DO: Digital Output Module
    • ERM: Expansion Receiver Module
    • GEIP: GE Intelligent Platforms/li>
    • I/O: Input / Output
    • LED: Light Emitting Diode
    • NIU: Network Interface Unit
    • OEM: Original Equipment Manufacturer
    • PSU: Power Supply Unit
    • PLC: Programmable Logic Controller
    • RAM: Random Access Memory
    • TB: Terminal Block
  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    1. Switch off the external power source to the power supply module.
    2. Turn the latch to the unlocked position.
    3. Press in the tabs on the lower edge of the power supply.
    4. Pull the power supply straight off (VersaMax® Modules, Power Supplies, and Carriers, 2003).
  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    1. The latch on the power supply must be in the unlocked position.
    2. Align the connectors, tab, and latch post on the power supply to be parallel with the CPU, NIU, ERM, or carrier.
    3. Press the power supply module down firmly, until the two tabs on the bottom of the power supply click into place. Be sure the tabs are fully inserted in the holes in bottom edge of the CPU, NIU, ERM, or booster carrier (VersaMax® Modules, Power Supplies, and Carriers, 2003).
    4. Turn the latch to the locked position to secure the power supply in place (VersaMax® Modules, Power Supplies, and Carriers, 2003).
  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    VersaMax® PLC CPUs IC200CPU001, CPU002, and CPU005 provide powerful PLC functionality in a small, versatile system. They are designed to serve as the system controller for up to 64 modules with up to 2048 I/O points. Two serial ports provide RS-232 and RS-485 interfaces for SNP slave and RTU slave communications (VersaMax® PLC User's Manual, 2006).

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    The CPU module has a convenient switch that can be used to place the PLC in Stop or Run mode. The same switch can also be used to block accidental writing to CPU memory and forcing or overriding discrete data. Use of this feature is configurable.

    The default configuration enables Run/Stop mode selection and disables memory protection (VersaMax® PLC User's Manual, 2006).

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    PowerOn when the CPU is receiving 5V power from the power supply. Does not indicate the status of the 3.3V power output.
    OKON indicates the CPU has passed its powerup diagnostics and is functioning properly. OFF indicates a CPU problem. Fast blinking indicates that the CPU is running its powerup diagnostics. Slow blinking indicates the CPU is configuring I/O modules. Simultaneous blinking of this LED and the gren RUN LED indicates that the CPU is in boot mode and is waiting for a firmware update through port 1.
    RUN
    • Green when the CPU is in Run mode.
    • Amber when the CPU is in Stop I/O Scan mode.
    • If LED is OFF but OK is ON, the CPU is in Stop/NO I/O Scan mode.
    • If this LED is flashing green and the Fault LED is ON, the module switch was moved from STOP to RUN mode while a fatal fault existed. Toggling the switch will continue to RUN mode.
    FALUT
    • ON if the CPU is in the Stop/Faulted mode becuase a fatal fault has occured.
    • To turn off the Fault LED, clear both the I/O Fault Table and the PLC Fault Table.
    • If this LED is blinking and the OK LED is OFF, a fatal fault was detected during PLC powerup diagnostics. Contact PLC Field Service
    ON If an override is active on a bit reference.
    Port 1/2 Blinking indicates activity on the respective port.

    The default configuration enables Run/Stop mode selection and disables memory protection (VersaMax® PLC User's Manual, 2006).

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    The CPUE05 has an Ethernet Interface port at the bottom right hand side for interfacing it with the plant Ethernet Network.

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    The CPUE05 has an Ethernet Interface port at the bottom right hand side for interfacing it with the plant Ethernet Network.

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    The Digital Input module interfaces the field digital inputs such as limit switches, pushbuttons, feedback signals etc. with the VersaMax PLC system.

  • Troubleshooting Guide for VersaMax PLC and I/O Modules.

    Individual Green LEDs indicate the on/off state of each input point. The Green OK LED is ON when backplane power is present to the module (VersaMax® Modules, Power Supplies, and Carriers, 2003).

  • The Digital Output module interfaces the field digital outputs such as valves, beacons, sounders etc. with the VersaMax PLC system.

  • Individual Green LEDs indicate the on/off state of the output points. Operation of these LEDs is dependent on field power but independent of load conditions.

    The green FLD PWR LED is ON when field power is applied to the module. The Green OK LED is on when backplane power is present to the module (VersaMax® Modules, Power Supplies, and Carriers, 2003).

  • The Analog Input module interfaces the field analog instruments such as transmitters, detectors etc. with the VersaMax PLC system.

  • The Green OK LED is ON when backplane power is present, internally generated field power is functioning properly, the module has been configured, and the module has been recognized on the backplane (VersaMax® Modules, Power Supplies, and Carriers, 2003).

    The module reports a Loss of Internal Power fault for field-side circuits. The module reports an Open Wire fault for each channel, when in 4-20mA mode (VersaMax® Modules, Power Supplies, and Carriers, 2003). These are however viewed in the I/O Fault table using the programming software (Machine Edition).

  • The Analog Output Module interfaces field analog output devices such as Control Valves, Display Meters etc. with the VersaMax PLC system.

  • The Green FLD PWR LED indicates the presence of user-side power for the analog field side circuits.

    The Green OK LED is ON when backplane power is present to the module.

This entry was posted on March 19th, 2015 and is filed under Support. Both comments and pings are currently closed.

Ge Versamax Software

Description

Ge Versamax Micro Plc Software

GE VersaMax Expansion Module IC200UEX626

Ge Fanuc Versamax Plc Software

Versamax
  • Extended Product Type : VersaMax
  • Product ID: IC200UEX626
  • GE Type Designation : VersaMax
  • Description: FAN IC200UEX626 6 CHANNEL ANALOG EXPANSION. (4) ANALOG INPUTS & (2) ANALOG OUTPUTS, 2 4VDC POWER SUPPLY (*INCLUDES IC200CBL501)

Features

Powerful and Reliable

  • VersaMax controllers provide powerful, reliable operation. Designed to minimize costs, these versatile controllers are easy to use and support and offer a wide range of I/O expansion modules and communications options.

Versamax Modular Provides Superior Versatility

  • VersaMax Modular is control and IO that can be snapped together to provide a compact node with a smaller footprint than typical control/IO combinations.

Versamax Micro Offers Big Performance in a Small Size

Ge Versamax Software

  • The Micro line of VersaMax controllers provide superior functionality in a compact package. Their modular design offers the features and flexibility to match your application needs, with fast cycle times, a robust instruction set, and extensive memory that expands programming options. Programming and configuration is simple and intuitive with Proficy Machine Edition software.
Versamax

Versamax Micro Plus Enhances Productivity

  • For an even greater productivity boost, VersaMax Micro Plus controllers feature more memory, high-precision motion and an advanced instruction set.
Ge versamax programming software
Ge Versamax Software

Description

Ge Versamax Micro Plc Software

GE VersaMax Expansion Module IC200UEX626

Ge Fanuc Versamax Plc Software

  • Extended Product Type : VersaMax
  • Product ID: IC200UEX626
  • GE Type Designation : VersaMax
  • Description: FAN IC200UEX626 6 CHANNEL ANALOG EXPANSION. (4) ANALOG INPUTS & (2) ANALOG OUTPUTS, 2 4VDC POWER SUPPLY (*INCLUDES IC200CBL501)

Features

Powerful and Reliable

  • VersaMax controllers provide powerful, reliable operation. Designed to minimize costs, these versatile controllers are easy to use and support and offer a wide range of I/O expansion modules and communications options.

Versamax Modular Provides Superior Versatility

  • VersaMax Modular is control and IO that can be snapped together to provide a compact node with a smaller footprint than typical control/IO combinations.

Versamax Micro Offers Big Performance in a Small Size

Ge Versamax Software

  • The Micro line of VersaMax controllers provide superior functionality in a compact package. Their modular design offers the features and flexibility to match your application needs, with fast cycle times, a robust instruction set, and extensive memory that expands programming options. Programming and configuration is simple and intuitive with Proficy Machine Edition software.

Versamax Micro Plus Enhances Productivity

  • For an even greater productivity boost, VersaMax Micro Plus controllers feature more memory, high-precision motion and an advanced instruction set.

Versamax Nano Delivers High Speed in Tight spaces

  • VersaMax Nano controllers combine the benefits of VersaMax Micro controllers with a smaller form factor. The VersaMax Nano is ideal for high-volume applications where cost and fast processor speeds are critical. With its all-in-one construction, installation is easy–and it fits in the palm of your hand.

Specification

  • Micro Type Restrictions : N/A
  • Number of Inputs/Outputs : 4 Channels In /2 Channels Out,Voltage or Current
  • Power Voltage : 24 VDC
  • Input Power Supply Rating : 3 Watts
  • 24 VDC User Power for Sensors : 200 mA
  • Dimensions (W x H x D) mm : 95 x 90 x 76